NFPA 1912 Fire Apparatus Refurbishing

Chapter 1 Administration

1.1* Scope

This standard specifies the minimum require­ments for the refurbishing of automotive fire apparatus utilized for fire fighting and rescue operations, whether the refurbish­ing is done at the fire department or municipal maintenance facilities, or at the facilities of private contractors or apparatus manufacturers.

1.2 Purpose.

This standard specifies the minimum require­ments for the refurbishing of automotive fire/rescue appara­tus, to ensure that any apparatus refurbished in accordance with this standard meets applicable motor vehicle regulations and applicable portions of the appropriate edition of the NFPA automotive fire apparatus standard.

  • Apparatus that receives a Level I refurbishing is intended to meet the current edition of the appropriate NFPA automo­tive fire apparatus standard.
  • Apparatus that receives a Level II refurbishing is inten­ded to meet the appropriate NFPA automotive fire apparatus standard in effect when the apparatus was originally construc­ted.
  • This standard is applicable to fire apparatus contracted for refurbishing on or after July 1, 2006; however, nothing shall prevent the use of the standard prior to July 1, 2006, if the purchaser and contractor agree. The standard is not intended to be applied retroactively.
  • This standard shall not apply to the repair of fire appara­tus.
  • Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength, fire resistance, effectiveness, durabil­ity, and safety over those prescribed by this standard.
  • Technical documentation shall be submitted to the authority having jurisdiction to demonstrate equivalency.
  • The system, method, or device shall be approved for the intended purpose by the authority

1.5* Units of Measure. In this standard, values for measure­ment in U.S. units are followed by an equivalent in metric units. Either set of values can be used but the same set of values (either U.S. units or metric units) shall be used consistently.

Chapter 2 Referenced Publications

  • The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered part of the requirements of this document.
  • NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471.

NFPA 1901, Standard for Automotive Fire Apparatus, 2016 edition.

NFPA 1906, Standard for Wildland Fire Apparatus, 2016 edition.

NFPA 1911, Standard for the Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2012 edition.

NFPA 1931, Standard for Manufacturer’s Design of Fire Depart- ment Ground Ladders, 2015 edition.

NFPA 1961, Standard on Fire Hose, 2013 edition. NFPA 1964, Standard for Spray Nozzles, 2013 edition.

Other Publications.

2.3.1 ANSI Publications. American National Standards Insti­tute, Inc., 25 West 43rd Street, 4th floor, New York, NY 10036.

ANSI A14.2, Ladders — Portable Metal — Safety Requirements, 2007.

ANSI A14.5, Ladders — Portable Reinforced Plastic — Safety Requirements, 2007.

ANSI/NEMA Z535.4, Product Safety Signs and Labels, 2011.

FAMA TC010, Standard Product Safety Sign Catalog for Automo­tive Fire Apparatus, 2012.

Fire Apparatus Safety Guide, 2014.

  • ISO Publications. International Organization for Stand­ardization, ch. de la Voie-Creuse, Case postale 56, CH-1211 Geneva 20, Switzerland, standardsinfo.net.

ISO 9244, Earth-moving machinery — Machine safety labels — General principles, 2008.

  • Other Publications. Merriam-Webster’s Collegiate Dictionary, 11th edition, Merriam-Webster, Inc., Springfield, MA 2003.

2.4 References for Extracts in Mandatory Sections.

NFPA 58, Liquefied Petroleum Gas Code, 2014 edition.

NFPA 58, Liquefied Petroleum Gas Code, 2014 edition. NFPA 1901, Standard for Automotive Fire Apparatus, 2016 edition.

NFPA 1906, Standard for midland Fire Apparatus, 2016 edition.

Chapter 3 Definitions

  • The definitions contained in this chapter shall apply to the terms used in this standard. Where terms are not defined in this chapter or within another chapter, they shall be defined using their ordinarily accepted meanings within the context in which they are used. Merriam-Webster’s Collegiate Dictionary, 11th edition, shall be the source for the ordinarily accepted meaning.
  • NFPA Official Definitions.

3.2.1* Approved. Acceptable to the authority having jurisdic­tion.

3.2.2* Authority Having Jurisdiction (AHJ). An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or a procedure.

  • Indicates a mandatory requirement.
  • Indicates a recommendation or that which is advised but not required.
  • An NFPA Standard, the main text of which contains only mandatory provisions using the word “shall” to indicate requirements and that is in a form generally suitable for mandatory reference by another standard or code or for adoption into law. Nonmandatory provisions are not to be considered a part of the requirements of a standard and shall be located in an appendix, annex, footnote, informational note, or other means as permitted in the NFPA Manuals of Style. When used in a generic sense, such as in the phrase “standards development process” or “standards development activities,” the term “standards” includes all NFPA Standards, including Codes, Standards, Recommended Practices, and Guides.

3.3 General Definitions.

  • An agreement between the purchasing authority and the contractor that the terms and conditions of the contract have been met.
  • Acceptance Tests. Tests performed on behalf of or by the purchaser at the time of delivery to determine compliance with the specifications for the fire apparatus.
  • Aerial Device. An aerial ladder, elevating platform, or water tower that is designed to position personnel, handle materials, provide continuous egress, or discharge water.
  • Aerial Fire Apparatus. A vehicle equipped with an aerial ladder, elevating platform, or water tower that is designed and equipped to support firefighting and rescue operations by positioning personnel, handling materials, providing continu­ous egress, or discharging water at positions elevated from the ground.
  • Aerial Ladder. A self-supporting, turntable-mounted, power-operated ladder of two or more sections permanendy attached to a self-propelled automotive fire apparatus and designed to provide a continuous egress route from an elevated position to the ground.
  • Angle of Approach. The smallest angle made between the road surface and a line drawn from the front point of ground contact of the front tire to any projection of the appa­ratus in front of the front axle.
  • Angle of Departure. The smallest angle made between the road surface and a line drawn from the rear point of ground contact of the rear tire to any projection of the appara­tus behind the rear axle.
  • Auxiliary Pump. A water pump mounted on the fire apparatus in addition to a fire pump and used for fire fighting either in conjunction with or independent of the fire pump.
  • Center of Gravity. The point at which the entire weight of the fire apparatus is considered to be concentrated so that, if supported at this point, the apparatus would remain in equili­brium in any position.
  • The basic operating motor vehicle including the engine, frame, and other essential structural and mechani­cal parts, but exclusive of the body and all appurtenances for the accommodation of driver, property, passengers, appliances, or equipment related to other than control. Common usage might, but need not, include a cab (or cowl).
  • A constituent part of a fire apparatus or system.
  • Continuous Egress. A continuous exit or rescue path down an aerial device from an elevated position to the ground. [1901,20161

3.3.13* Contractor. The person or company responsible for fulfilling an agreed-upon contract. 

  • A discontinuity in a part or a failure to function that interferes with the service or reliability for which the part was intended.
  • Elevating Platform. A self-supporting, turntable- mounted device consisting of a personnel-carrying platform attached to the uppermost boom of a series of power-operated booms that articulate, telescope, or both and that are some­times arranged to provide the continuous egress capabilities of an aerial ladder.
  • Estimated In-Service Weight. The amount that the fire apparatus manufacturer estimates the apparatus will weigh when it is placed in service with all fixed and portable equip­ment installed, all tanks full, and all personnel seating positions occupied.
  • Final-Stage Manufacturer. An entity that performs such manufacturing operations on an incomplete vehicle that it becomes a complete vehicle.
  • Fire Apparatus. A vehicle designed to be used under emergency conditions to transport personnel and equipment or to support the suppression of fires or mitigation of other hazardous situations.
  • Fire Pump. A water pump with a rated capacity of at least 250 gpm (1000 L/min) but less than 3000 gpm (12,000 L/min) at 150 psi (1000 kPa) net pump pressure, or a water pump with rated capacity of 3000 gpm (12,000 L/min) or greater at 100 psi (700 kPa) net pump pressure that is mounted on a fire apparatus and intended for fire fighting. [1901,20161
  • Gallon, U.S. Standard. 1 U.S. gal = 0.833 Imperial gal = 231 in.3 = 3.785 L. [58, 2014]
  • A visual device that indicates a measurement.

3.3.22* GAWR (Gross Axle Weight Rating). The final-stage chassis manufacturer’s specified maximum load-carrying capacity of an axle system, as measured at the tire-ground interfaces.

3.3.23* GCWR (Gross Combination Weight Rating). The final- stage manufacturer’s specified maximum loaded weight for a combination (articulated) vehicle consisting of a tow vehicle and one or more towed units.

3.3.24* Grade. A measurement of the angle used in road design and expressed as a percentage of elevation change over distance.

3.3.25* GVWR (Gross Vehicle Weight Rating). The final-stage manufacturer’s specified maximum load-carrying capacity of a single vehicle. [1901,20161

  • Initial Attack Apparatus. Fire apparatus with a fire pump of at least 250 gpm (1000 L/min) capacity, water tank, and hose body whose primary purpose is to initiate a fire suppression attack on structural, vehicular, or vegetation fires, and to support associated fire department operations.
  • Line-Voltage Circuit, Equipment, or System. An ac or dc electrical circuit, equipment, or system where the voltage to ground or from line to line is greater than 30 V rms (ac), 42.4 V peak (ac), or 60 V dc.
  • Low-Voltage Circuit, Equipment, or System. An electri­cal circuit, equipment, or system where the voltage does not exceed 30 V rms (ac), 42.4 V peak (ac), or 60 V dc; usually 12 V dc in fire apparatus.
  • The entity responsible for the assembly of a finished product from materials or components.
  • Mobile Foam Fire Apparatus. Fire apparatus with a permanendy mounted fire pump, foam proportioning system, and foam concentrate tank(s) whose primary purpose is the control and extinguishment of flammable and combustible liquid fires in storage tanks and spills. 
  • Mobile Water Supply Apparatus (Tanker, Tender). A vehicle designed primarily for transporting (pickup, transport­ing, and delivering) water to fire emergency scenes to be applied by other vehicles or pumping equipment.

3.3.32* Net Pump Pressure. The sum of the discharge pres­sure and the suction lift converted to psi or kPa when pumping at draft, or the difference between the discharge pressure and the intake pressure when pumping from a hydrant or other source of water under positive pressure.

A person qualified to operate a fire appara­tus.

  • Pump Operator’s Panel. The area on a fire apparatus that contains the gauges, controls, and other instruments used for operating the pump.
  • Pump Operator’s Position. The location from which the pump operator operates the pump.
  • Fire apparatus with a permanently mounted fire pump of at least 750 gpm (3000 L/min) capacity, water tank, and hose body whose primary purpose is to combat struc­tural and associated fires.

3.3.37* Purchaser. The authority having responsibility for the specification and acceptance of the apparatus.

3.3.38 Purchasing Authority. The agency that has the sole responsibility and authority for negotiating, placing, and, where necessary, modifying each and every solicitation, purchase order, or other award issued by a governing body. 11901,20161

3.3.39* Quint. Fire apparatus with a permanently mounted fire pump, a water tank, a hose storage area, an aerial ladder or elevating platform with a permanendy mounted waterway, and a complement of ground ladders.

  • Rated Capacity (Aerial Device). The total amount of weight of all personnel and equipment that can be supported at the outermost rung of an aerial ladder or on the platform of an elevating platform with the aerial device placed in the hori­zontal position at its maximum horizontal extension when the stabilizers are fully deployed.
  • Rated Capacity (Water Pump). The flow rate to which the pump manufacturer certifies compliance of the pump when it is new.

3.3.42.1* Level I Refurbishing. The assembly of a new fire apparatus by the use of a new chassis frame, driving and crew compartment, front axle, steering and suspension components, and the use of either new components or components from an existing apparatus for the remainder of the apparatus.

3.3.42.2* Level II Refurbishing. The upgrade of major components or systems of a fire apparatus with components or systems that comply with the applicable standards in effect at the time the original apparatus was manufactured.

  • To restore to sound condition after failure or damage.
  • The removal of an existing component or system and the installation of a similar component or system generally of the same model or the same capability (i.e., “like for like” replacement).

3.3.45* Special Services Fire Apparatus. A multipurpose vehi­cle that primarily provides support services at emergency scenes.

  • Suspension System. The components utilized to attach the axle(s) to the frame assembly.
  • See 3.3.31, Mobile Water Supply Apparatus.
  • See 3.3.31, Mobile Water Supply Apparatus.
  • A structural component that connects the aerial device to the chassis and stabilization system through a rotating bearing that permits 360-degree continuous rotation of the aerial device.
  • Unequipped Fire Apparatus. The completed fire appa­ratus excluding personnel, agent(s), and any equipment removable without the use of tools.

3.3.51* Upgrade. The substitution or addition of components or systems with new components or systems with improved performance or capability.

  • Water Tower. An aerial device consisting of perma- nendy mounted power-operated booms that articulate, tele­scope, or both, and a waterway designed to supply a large- capacity, mobile, elevated water stream.
  • Wildland Fire Suppression Apparatus. A fire apparatus designed for fighting wildland fires that is equipped with a pump, a water tank, limited hose and equipment, and pump- and-roll capability.

Chapter 4 General Requirements

4.1* General.

  • Fire apparatus receiving Level I refurbishing shall meet the requirements of applicable chapters of the current edition of NFPA 1901 if the apparatus is not a wildland fire apparatus, or NFPA 1906 if the apparatus is a wildland fire apparatus, except as noted in Chapter 5.
  • Fire apparatus receiving Level II refurbishing shall meet the requirements of applicable chapters of the edition of the NFPA automotive fire apparatus standard that was in effect at the time of its original manufacture, except as noted in Chap­ter 6.

4.2* Responsibility of Purchaser. It shall be the responsibility of the purchaser to specify the details of the fire apparatus refurbishing; its required performance, including where opera­tions at elevations above 2000 ft (600 m) or on grades greater than 6 percent are required; the maximum number of fire fighters to ride within the apparatus; specific added continuous electrical loads that exceed the minimum of this standard; and any hose, ground ladders, or equipment to be carried by the apparatus that exceed the minimum requirements of this standard.

  • Responsibility of the Contractor.

4.3.1* The contractor shall provide a detailed description of the refurbished fire apparatus, a list of equipment to be furnished, and other construction and performance details to which the apparatus shall conform.

4.3.2* Responsibility for the fire apparatus and equipment shall remain with the contractor until such responsibilities are accepted by the purchaser.

  • Fire Apparatus Components. All components shall be installed in accordance with that component manufacturer’s installation instructions.
  • Fire Pump. If the fire apparatus is equipped with a new fire pump, the pump and its associated equipment shall meet the requirements for fire pumps in the current edition of NFPA 1901.
  • Auxiliary Pump. If the fire apparatus is equipped with a new auxiliary pump, the pump and its associated equipment shall meet the requirements for auxiliary pumps in the current edition of NFPA 1901.
  • Wildland Water Pump. If the fire apparatus is equipped with a new wildland water pump, the pump and its associated equipment shall meet the requirements for water pumps in the current edition of NFPA 1906.
  • Water Tank. If the fire apparatus is equipped with a new water tank, the water tank shall meet the requirements for water tanks in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Aerial Device. If the fire apparatus is equipped with a new aerial device (i.e., aerial ladder, elevating platform, or water tower), the aerial device shall meet the requirements for aerial devices in the current edition of NFPA 1901.
  • Foam Proportioning System. If the fire apparatus is equipped with a new foam proportioning system, the apparatus shall meet the requirements for foam proportioning systems in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Compressed Air Foam System. If the fire apparatus is equipped with a new compressed air foam system, the system shall meet the requirements for compressed air foam systems in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Line-Voltage Electrical System. If the fire apparatus is equipped with a new line-voltage electrical system or compo­nents, the system or components shall meet the requirements for line-voltage electrical systems in the current edition of NFPA 1901.
  • Command and Communications. If the fire apparatus is equipped with a new command and communications area, the area shall meet the requirements for command and communi­cations areas in the current edition of NFPA
  • Air System. If the fire apparatus is equipped with a new air system, the system shall meet the requirements for air systems in the current edition of NFPA 1901.

4.4.11 Winch System. If the fire apparatus is equipped with a new winch system, the system shall meet the requirements for winches in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.

4.5 Chassis Components. Each component shall be installed in accordance with that component manufacturer’s installation instructions.

  • If the fire apparatus is equipped with a new engine, the system shall meet the requirements for engines in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Transmission/Transfer Case. If the fire apparatus is equipped with a new transmission or transfer case, the compo­nents) shall meet the requirements for transmissions and transfer cases in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Braking System. If the fire apparatus is equipped with a new braking system, the system shall meet the requirements for braking systems in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Axle(s). If the fire apparatus is equipped with a new axle(s), the component(s) shall meet the requirements for axles in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Suspension, Wheels, and Tires. If the fire apparatus is equipped with new suspension, wheels, or tires, the compo­nents) shall meet the requirements for new suspension, wheels, and tires in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Cooling System. If the fire apparatus is equipped with a new cooling system, the system shall meet the requirements for cooling systems in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Low-Voltage Electrical System. If the fire apparatus is equipped with a new low-voltage electrical system or compo­nents, the system or components shall meet the requirements for low-voltage electrical systems in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the fire apparatus is equipped with a new chas­sis frame, the frame shall meet the requirements for chassis frames in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the fire apparatus is equipped with a new driveline, the components shall meet the requirements for drivelines in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Lubrication System. If the fire apparatus is equipped with a new lubrication system, the system shall meet the requirements for lubrication systems in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Fuel and Air System. If the fire apparatus is equipped with a new fuel and air system, the system shall meet the requirements for fuel and air systems in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Exhaust System. If the fire apparatus is equipped with a new exhaust system, the system shall meet the requirements for exhaust systems in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.

4.5.13 Driving and Crew Compartment. If the fire apparatus is equipped with a new driving and crew compartment, the assembly shall meet the requirements for driving and crew compartments in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.

  • Governmental Requirements. The fire apparatus shall comply with all applicable federal and state motor vehicle laws and regulations.
  • Personnel Protection.

4.7.1* Guards, shields, or other protection shall be added to refurbished fire apparatus where necessary to prevent injury to personnel by hot, moving, or rotating parts during normal nonmaintenance operations.

  • Electrical insulation or isolation shall be provided where necessary to prevent electrical shock from onboard electrical systems.
  • Vehicular workmanship shall ensure a safe operating environment free of accessible sharp projections and edges.

4.7.4* Safety signs with text shall conform to the general prin­ciples of ANSI/NEMA Z535.4, Product Safety Signs and Labels. Safety signs without text shall conform to the general principles for two-panel safety signs of ISO 9244, Earth-moving machinery — Machine safety labels— General principles. [1901:4.9.4]

  • Apparatus built for sale in the United States shall employ safety signage that complies with ANSI/NEMA Z535.4. [1901:4.9.4.11
  • Apparatus built for sale outside the United States shall employ safety signage that complies with either ANSI/NEMA Z535.4 or ISO 9244. [1901:4.9.4.2]

4.8* Carrying Capacity. The GAWR and GCWR or GVWR of the chassis shall be adequate to carry the weight of the fire apparatus when loaded to its estimated in-service weight as defined in 4.8.2.

  • The contractor shall establish the estimated in-service weight during the design of the work to be done in refurbish­ing the fire apparatus.
  • The estimated in-service weight shall include the follow­ing:
    • The chassis, body, and tank(s)
    • Full fuel, lubricant, and other chassis or component fluid tanks or reservoirs
    • Full water and other agent tanks
    • * 200 lb (90 kg) in each seating position
    • 70 lb (32 kg) for each seating position for personal gear unless specified as not applicable
    • Fixed equipment such as pumps, aerial devices, genera­tors, reels, and air systems as installed
    • Ground ladders, suction hose, designed hose load in their hose beds and on their reels
    • An allowance for miscellaneous equipment as provided by the purchaser
  • The contractor shall engineer and design the work that will occur to the fire apparatus during the refurbishment such that the completed apparatus, when loaded to its estimated in- service weight, with all movable weights distributed as close as practical to their intended in-service configuration, does not exceed the gross vehicle weight rating (GVWR).

Chapter 5 Level I Refurbishing

5.1* General. Fire apparatus refurbished to Level I standards shall meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable, for those components unless specified otherwise in this chapter.

5.2* Carrying Capacity. If a fire apparatus system or compo­nent is to be upgraded, the contractor shall ensure that the completed apparatus does not exceed the GAWR and GCWR, or GVWR, of the chassis when carrying the estimated in-service weight of the unequipped apparatus as defined in 4.8.2.

  • Vehicle Stability.
  • When the apparatus is loaded to its estimated in-service weight, the height of the vehicle’s center of gravity shall not exceed the chassis manufacturer’s maximum limit.
  • When the apparatus is loaded to its estimated in-service weight, the front-to-rear weight distribution on the vehicle shall be within the limits set by the chassis manufacturer.
  • Front axle loads shall not be less than the minimum axle loads specified by the chassis manufacturer, under full load and all other loading conditions.

5.3.4* The fire apparatus, when loaded to its estimated in- service weight, shall have a side-to-side tire load variation of no more than 7 percent of the total tire load for that axle.

5.3.5* A lateral acceleration indicator that is adjustable for sensitivity and that provides both visual and audio signals and warnings to the driver shall be provided as an alternative to tilt table testing, or in circumstances where the vehicle is unable to meet tilt table requirements as referenced in NFPA 1901.

  • The fire apparatus frame shall be replaced with a new chassis frame meeting the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.
  •  
  • If the original drivetrain or associated components are used, the contractor shall perform a thorough inspection of the drivetrain components not scheduled for replacement (such as the drive shaft, end yokes or flanges, universal joints, and associated mountings) for wear, balance, stress cracks, or other damage.
  • The contractor shall notify the purchaser in writing of any damage discovered during the inspection.
  • If a new drivetrain or associated components are instal­led, the contractor shall certify that the installation meets the component manufacturer’s recommendations.
  • Engine and Engine System Design.

5.6.1 If the original engine and accessories are used, the contractor shall perform a thorough inspection of the engine and related accessories including, but not limited to, mount­ings, fan belts, and filters.

5.6.1.1 The inspection shall check for wear, fluid leaks, loss of power, and other potential problems.

  • The contractor shall notify the purchaser in writing of all necessary repairs and services needed to bring the engine and related accessories within the engine manufacturer’s origi­nal specifications.
  • All belts and filters shall be replaced.

5.6.2* If the existing engine and/or engine system is to be replaced, it shall be replaced with one that meets the current requirements of NFPA 1901 or NFPA 1906, whichever is appli­cable.

5.6.2.1 The contractor shall furnish certification that the engine meets Environmental Protection Agency (EPA) stand­ards that were in effect at the time of contract signing as well as certification that the installation meets the engine manufactur­er’s specifications.

  • Cooling System.
  • If the original cooling system is to be reused, the contrac­tor shall perform a thorough inspection of the cooling system for leaks, blockages, wear, or other problems that could affect vehicle engine cooling.
  • The contractor shall notify the purchaser in writing of any problems discovered during the inspection.
  • The cooling system shall be flushed, and new coolant meeting the engine manufacturer’s specifications shall be added.
  • If the cooling system is to be replaced, it shall be replaced with one that meets the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable, as well as the engine manufacturer’s specifications.
  • Lubrication System.
  • If the original lubrication system is to be reused, the contractor shall perform a thorough inspection of the lubrica­tion system for leaks, blockages, or other problems that could affect vehicle lubrication.

5.8.1.1 The contractor shall notify the purchaser in writing of any problems discovered during the inspection.

  • If the lubrication system is to be replaced, it shall be replaced with one that meets the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable, and the engine manufacturer’s standards.
  • Fuel and Air Systems. The fire apparatus fuel and air intake systems shall be replaced with new fuel and air intake systems that meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable, and the engine manufac­turer’s standards.
  • Exhaust System. The original fire apparatus exhaust system shall be replaced with a new exhaust system that meets the current requirements of NFPA 1901 or NFPA 1906, which­ever is applicable, and the engine manufacturer’s standards.
  • Vehicle Components. 5.11.1 Braking System.

5.11.1.1 The contractor shall certify that the braking system meets the performance requirements of the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.

  • When a new braking system or brake components are installed, the contractor shall certify that the installation meets the component manufacturer’s requirements.
  • Parking brakes shall control the rear wheels, or all wheels, and shall be of the positive, mechanically actuated type.

5.11.1.3.1* When the fire apparatus, as delivered, is loaded to its GVWR or GCWR, if applicable, the parking brake system shall hold the apparatus on at least a 20 percent grade.

  • A lockup device to retain applied pressure on hydraulically actuated service brake systems, or the use of the “park” position on an automatic transmission shall not be substituted for a separate parking brake system.
  • Parking brakes on steerable axles of tiller vehicles shall be provided where necessary to meet the requirements of this standard.
  • Air-applied brakes or mechanically actuated brakes shall be acceptable on steerable axles of tiller vehicles.
  • All fire apparatus with a GVWR of 36,000 lb (16,000 kg) or greater shall be equipped with an auxiliary brak­ing system.
  • Suspension, Wheels, and Tires.

5.11.2.1 The suspension system shall be replaced with a new suspension system that meets the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.

5.11.2.2* If the existing axle(s), wheels, or tires are utilized, the contractor shall inspect and verify the condition of these components for continued use in emergency service.

5.11.2.2.1 Damaged components shall be repaired or replaced.

  • The contractor shall certify that the axles, wheels, and tires of the completed fire apparatus meet all current federal and state GVWR, GCWR, and GAWR requirements.
  • Angle of Approach and Departure.
  • If the fire apparatus is being refurbished to NFPA 1901, an angle of approach and an angle of departure of at least 8 degrees shall be maintained at the front and rear of the vehicle when it is loaded to its GVWR or GCWR, if applica­ble.
  • If the fire apparatus is being refurbished to NFPA 1906, an angle of approach and an angle of departure of at least 20 degrees shall be maintained at the front and rear of the vehicle when it is loaded to its GVWR or GCWR, if applica­ble.
  • The fire apparatus steering system shall be replaced with a new steering system meeting the current requirements of NFPA 1901 or NFPA 1906, whichever is appli­cable.
  • Transmission/Transfer Case.

5.11.4.1 If either the original transmission or the transfer case is reused, the contractor shall inspect the transmission or trans­fer case, its mountings, and any associated accessories for wear, damage, and fluid leaks.

5.11.4.1.1 The contractor shall notify the purchaser in writing of any problems discovered during the inspection.

5.11.4.1.2 All fluids and filters shall be changed.

5.11.4.2 In the event a new or refurbished transmission or transfer case is installed in the fire apparatus, the contractor shall certify that the installation meets the transmission or transfer case manufacturer’s specifications for installation on that specific type of apparatus.

  • Fuel Tank. The fire apparatus fuel tank shall be replaced with a new tank that meets the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Tow Hooks. Front or rear tow hooks or tow eyes shall be attached to the frame structure to allow towing (not lifting) of the fire apparatus without damage.

5.12 Low-Voltage Electrical Systems and Warning Devices. The

fire apparatus electrical wiring system and warning devices shall be replaced with a complete new system that meets the current requirements of NFPA 1901 or NFPA 1906, whichever is appli­cable.

5.13* Driving and Crew Compartments. The fire apparatus driving and crew compartments shall be replaced with new driving and crew compartments that meet the current require­ments of NFPA 1901 or NFPA 1906, whichever is applicable, and the chassis manufacturer’s standards.

  • Body, Compartmentation, and Hose Storage.
  • If the original fire apparatus body is to be reused, it shall be inspected for serviceability and upgraded to meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the fire apparatus body, compartmentation, and hose storage areas are to be replaced, they shall be replaced with components that meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If new compartments are to be added to an existing fire apparatus body, they shall meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.

5.14.4* The fire apparatus shall comply with the current requirements for metal finish in NFPA 1901 or NFPA 1906, whichever is applicable, including the application of reflective striping.

  • Fire Pump and Associated Equipment.
  • If the original fire pump is reused, the contractor shall inspect the fire pump, its mountings, and its associated accesso­ries for wear, damage, and leaks.
  • The contractor shall notify the purchaser in writing of any problems discovered during the inspection.
  • All new or upgraded parts or components shall meet the current requirements of NFPA 1901 or NFPA 1906, which­ever is applicable.
  • The pump packing shall be adjusted according to the pump manufacturer’s recommendations.
  • Water Tanks.

5.16.1 If the existing water tank is to be reused, the contractor shall inspect the water tank for serviceability and report any defects to the purchaser in writing.

5.16.2* If a new water tank is installed, it shall meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.

5.16.2.1 Installation of a new water tank shall not result in the completed fire apparatus exceeding the GAWR and GCWR or GVWR of the chassis under the conditions specified in Section 5.2.

  • Aerial Devices.
  • If the original aerial device is to be used, a full inspec­tion and test as defined in NFPA 1911 shall be performed.

5.17.1.1 A test shall be performed prior to refurbishing to determine the condition of the aerial device.

  • If the original aerial device is reused, it shall meet the requirements of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.
  • After the aerial device upgrade work has been performed, a full inspection and test as defined in NFPA 1911 shall be performed.
  • Equipment Carried on Fire Apparatus.
  • If new ground ladders are furnished, they shall meet the requirements of NFPA 1931.
  • Stepladders and other types of multipurpose ladders meeting ANSI A14.2, Ladders — Portable Metal — Safety Require­ments, or ANSI A14.5, Ladders — Portable Reinforced Plastic — Safety Requirements, with duty ratings of Type 1A or 1AA shall be permitted to be substituted for a folding ladder.
  • Stepladders and other types of multipurpose ladders shall be permitted to be carried in addition to the minimum fire department ground ladders specified in NFPA 1901 provi­ded they meet either ANSI A14.2 or ANSI A14.5 with duty ratings of Type 1A or 1AA.
  • If new hose is furnished, it shall meet the requirements of NFPA 1961.
  • If new nozzles are furnished, they shall meet the requirements of NFPA 1964.
  • Tests and Delivery Data Requirements. 5.19.1 Fire Apparatus Certification Tests.
  • If the refurbished fire apparatus is equipped with a fire pump that has a rated capacity of 750 gpm (3000 L/min) or greater, the pump system shall be tested after the pump and all its associated piping and equipment have been installed on the apparatus.
  • The tests shall be conducted at the contractor’s approved facility and certified by an independent testing organization approved by the purchaser.
  • The certification shall include at least the tests defined in 5.19.2 through 5.19.6.
  • If the apparatus is equipped with a water tank, the water tank-to-pump flow test defined in 5.19.7 shall be inclu­ded.
  • If the refurbished fire apparatus is equipped with a fire pump that has a rated capacity of less than 750 gpm (3000 L/min), the pump shall be tested after the pump and all its associated piping and equipment have been installed on the apparatus.
  • The tests shall be conducted at the manufacturer’s approved facility and certified by the contractor.
  • The certification shall include at least the tests defined in 5.19.2 and 5.19.4 through 5.19.6.
  • If the apparatus is equipped with a water tank, the water tank-to-pump flow test defined in 5.19.7 shall be inclu­ded.
  • Pumping Tests. A pumping certification test shall be conducted in accordance with the test requirements defined in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Pumping Engine Overload Test.
  • If a new fire pump is installed, a pumping engine overload test shall be conducted in accordance with the test requirements defined in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the original fire pump is retained or reused, a pumping engine overload test shall be conducted in accord­ance with the test requirements of the NFPA automotive fire apparatus standard that was in effect at the time of the contract signing for the original manufacture of the apparatus.
  • Pressure Control System Test.
  • If the refurbished fire apparatus is equipped with a new pressure control system on the fire pump, it shall be tested in accordance with the test requirements defined in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the original pressure control system is retained or reused, it shall be tested in accordance with the pressure control device testing requirements of NFPA 1911.
  • Priming System Test.
  • If the refurbished fire apparatus is equipped with a new priming system on the fire pump, it shall be tested in accordance with the test requirements defined in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the original priming system is retained or reused, it shall be tested in accordance with the priming system test requirements of NFPA 1911.
  • Vacuum Test.
  • If the refurbished fire apparatus is equipped with a new fire pump, a vacuum test shall be conducted in accordance with the test requirements defined in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the original fire pump is retained or reused, a vacuum test shall be conducted in accordance with the test requirements of NFPA 1911.
  • Water Tank-to-Pump Flow Test.

5.19.7.1 If the refurbished fire apparatus has a new water tank(s), fire pump(s), or pump piping, a water tank-to-pump flow test shall be conducted in accordance with the test requirements in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.

5.19.7.2 If the original water tank(s), pump(s), and pump piping is retained or reused, a water tank-to-pump flow test shall be conducted to ensure the installation meets the require­ments of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.

  • Engine Speed Advancement Interlock Test. An engine speed advancement interlock test meeting the test require­ments in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable, shall be conducted.
  • Aerial Device Certification Tests. If a new or reutilized aerial device is installed on the refurbished fire apparatus, the completed apparatus shall be tested at the manufacturer’s approved facility and certified by an independent testing organization approved by the purchaser.
  • New aerial devices shall be tested according to the current edition of NFPA 1901.
  • Reutilized aerial devices shall be tested to the NFPA automotive fire apparatus standard in effect at the time of the original aerial device manufacture.
  • Refurbisher’s Pre-Delivery Tests.
  • Water Tank Capacity Test. If the refurbished fire apparatus has a new water tank, the water tank manufacturer shall certify the capacity of the water tank and the certification shall be provided to the purchaser when the apparatus is deliv­ered.

5.19.10.1.1 If the refurbished fire apparatus retains or reuses the original water tank, the tank shall be tested to ensure it meets the requirements of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.

  • Piping Hydrostatic Test.
  • If the refurbished fire apparatus has a new fire pump or pump piping system, a piping hydrostatic test shall be conducted in accordance with the test requirements in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the refurbished fire apparatus retains or reuses the original pump(s) and pump piping, a piping hydrostatic test shall be conducted to ensure the integrity of the piping installation meets the requirements of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.
  • Electrical System Tests. Electrical system tests shall be conducted in accordance with the test requirements in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable, on all refurbished fire apparatus.

5.19.10.4* Foam System Tests.

  • If the refurbished fire apparatus has a newly instal­led foam system or system components, the system shall be tested in accordance with the test requirements in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the refurbished fire apparatus reuses the original foam systems and system components, the system shall be tested to ensure it meets the requirements of the NFPA auto­motive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.

5.19.11* Road Tests.

  • If the refurbished fire apparatus has any upgraded powertrain components (engine, transmission, driveline, or axles), it shall be road tested in accordance with 5.19.11.4 through 5.19.11.8.
  • If the refurbished fire apparatus reuses all of the original powertrain components (engine, transmission, drive- line, and axles), it shall be tested to ensure it meets the require­ments of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.
  • The tests shall be conducted at a location and in a manner that does not violate local, state, or federal traffic laws.
  • The fire apparatus shall be loaded to its estimated in- service weight.
  • The tests shall be conducted on dry, level, paved roads that are in good condition.
  • The engine shall not be operated in excess of the maximum governed speed.
  • Acceleration tests shall consist of two runs in oppo­site directions over the same route.
  • The vehicle shall attain a speed of 35 mph (55 km/hr) from a standing start within 25 seconds.
  • The vehicle shall attain a minimum top speed of not less than 50 mph (80 km/hr).
  • If the fire apparatus is equipped with an auxiliary braking system, the manufacturer shall road test the system to confirm that the system is functioning as intended by the auxili­ary braking system manufacturer.
  • If the apparatus is equipped with an air brake system, the service brakes shall bring the apparatus, when loaded to its GVWR, to a complete stop from an initial speed of 20 mph (32.2 km/hr), in a distance not exceeding 35 ft (10.7 m) by actual measurement on a paved, level, dry surface road that is free of loose material, oil, or grease.
  • If the apparatus is equipped with a hydraulic brake system, the service brakes shall bring the apparatus, when loaded to its GVWR, to a complete stop from an initial speed of 30 mph (48.2 km/hr), in a distance not exceeding 88 ft (26.8 m) by actual measurement on a paved, level, dry surface road that is free of loose material, oil, or grease.

5.19.12 Tests on Delivery.

  • If acceptance tests are required at the point of deliv­ery, the purchaser shall specify the details of the tests to be performed and they shall not be performed in a manner that requires the apparatus or a component to operate outside its designed operating range.
  • Aerial device stability tests shall not be run at other than the refurbisher’s or the aerial device manufacturer’s facility.
  • Data Required of the Contractor.
  • The contractor shall supply, at the time of delivery, at least two copies of complete operation, service, and parts manuals covering the completed fire apparatus as delivered and accepted.
  • This requirement shall be permitted to be adjusted to cover only manuals for those new components or systems that are changed from the original configuration.
  • The requirement for either complete or partial manuals shall be supplied by the purchasing authority.
  • The contractor shall supply, at the time of delivery, at least one copy of the following:
    • Engine manufacturer’s certified brake horsepower curve for a new engine installation showing the maximum governed speed
    • Contractor’s record of fire apparatus refurbishing, includ­ing, if applicable, all technical information required for inspection to comply with NFPA 1911
    • Pump manufacturer’s certification of suction capabilities for new pump installations
    • Pump manufacturer’s certification of hydrostatic test for new pump installations
    • Certification of inspection and test
    • If the apparatus is equipped with a pump, a copy of the chassis manufacturer’s approval for stationary pumping applications
    • Weight documents from a certified scale showing actual loading on the front axle, rear axle(s), and overall vehicle (with the water tank full but without personnel, equip­ment, and hose) to determine compliance with Section 4.8
    • The latest edition of the FAMA Fire Apparatus Safety Guide
  • A label shall be affixed to the vehicle certifying that the vehicle is in compliance with all applicable Federal Motor Vehi­cle Safety Standards (FMYSS) in effect at the time of comple­tion.
  • If the original fire pump is replaced with a new fire pump, a new test plate shall be provided on the pump opera­tor’s panel.
  • The new test plate shall give the rated discharges and pressures, together with the speed of the engine, as determined by the certification test for each unit; the position of the paral­lel-series pump as used; and the governed speed of the engines as stated by the engine manufacturer on a certified brake horsepower curve.
  • The test plate shall be stamped with complete infor­mation at the contractor’s facility and attached to the vehicle prior to delivery.
  • Safety Signs. The contractor shall ensure that the follow­ing safety signs, as appropriate to the apparatus type and features an das described and located per FAMA TC010, Stand­ard Product Safety Sign Gatalog for Automotive Fire Apparatus, shall be on the apparatus prior to delivery:
    • FAMA01 — Battery Explosion
    • FAMA02 — Rotating Shafts
    • FAMA05 — Spinning Fan
    • FAMA06 — Seats Without Belts Not Occupied
    • FAMA07 — Seated and Belted
    • FAMA 10 — Cab Equipment Mounting
    • FAMA 12 — Fire Service Tire Rating
    • FAMA14 —Cab Seating
    • FAMA 15 — Helmet Worn in Cab (1901 Municipal Appa­ratus)
    • FAMA17 — Vehicle Backing
    • FAMA 18 — Intake and Discharge Cap Pressure
    • FAMA22 — Hose Restraint Required
    • FAMA23 — Access Step Method
    • FAMA24 — Riding on Exterior
    • FAMA25 — Trained Personnel Only — NFPA Required
    • FAMA26 — No-Step
    • FAMA28 — Rope Tie-Down 9000
    • FAMA30 — Stabilize r Crush
    • FAMA31 — Stabil ize r Pins & Pads
    • FAMA32 — Stabilizer Pads
    • FAMA34 — Fall Restraint Required
    • FAMA35 — Aerial Electrocution
    • FAMA36 — Aerial Electrocution
    • FAMA37 — Aerial Device Load Capacity
    • FAMA38 — Aerial Ladder Rung Pinch ‘
    • FAMA39 — Aerial Inspection
    • FAMA41—Cab Tilt
    • FAMA42 — Siren Noise
    • FAMA43 — Helmet Worn in Cab (1906 Wildlands Appa­ratus)
    • FAMA44 — Pump-and-Roll Firefighting Position Exte­rior
    • FAMA45 — Pump-and-Roll Firefighting Position Driver
    • FAMA46 — Aerial Device Pinch
    • FAMA47 — Aerial Device Operator Attention Required

Chapter 6 Level II Refurbishing

6.1* General. All new or upgraded components utilized in Level II refurbishing shall meet the requirements of the current edition of NFPA 1901 or NFPA 1906, whichever is applicable, for those components, unless otherwise specified in this chapter.

  • The purchaser shall specify which components and systems are to be upgraded.
  • Any upgraded system shall be compatible with its associ­ated components.
  • Systems or components that are not compatible shall not be installed on the refurbished fire apparatus.

6.2* Carrying Capacity. If a fire apparatus system or compo­nent is to be upgraded, the contractor shall ensure that the refurbished apparatus does not exceed the GAWR and GCWR, or GVWR, of the chassis when carrying the estimated in-service weight of the unequipped apparatus as defined in 4.8.2.

6.3* Vehicle Stability.

6.3.1* When the apparatus is loaded to its estimated in-service weight, the height of the vehicle’s center of gravity shall not exceed the chassis manufacturer’s maximum limit.

6.3.2* When the apparatus is loaded to its estimated in-service weight, the front-to-rear weight distribution on the vehicle shall be within the limits set by the chassis manufacturer.

6.3.3 Front axle loads shall not be less than the minimum axle loads specified by the chassis manufacturer, under full load and all other loading conditions.

6.3.4* The fire apparatus, when loaded to its estimated in- service weight, shall have a side-to-side tire load variation of no more than 7 percent of the total tire load for that axle.

  •  
  • If the apparatus’ frame is to be upgraded, all parts of the frame not scheduled to be replaced shall be inspected for wear, broken or loose bolts or other fittings, bent or damaged members, or other problems.
  • The contractor shall notify the purchaser in writing of any problems or abnormal conditions discovered during the inspection.
  •  
  • If the apparatus drivetrain is to be upgraded, the contrac­tor shall inspect all components of the drivetrain not scheduled to be replaced for wear, balance, stress cracks, or other damage.
  • The inspection shall include the drive shaft, end yokes or flanges, universal joints, and associated mountings.
  • The contractor shall notify the purchaser in writing of any damaged components or other problems discovered during the inspection.
  • If a new drivetrain or associated components are installed or existing components are modified, the contractor shall ensure that the installation meets the component manufactur­er’s recommendations.
  • Engine and Engine System Design.

6.6.1* If the engine or an engine system component(s) is upgraded, the contractor shall inspect the engine and all rela­ted accessories that are not scheduled to be replaced for wear, fluid leaks, loss of power, excessive smoke, or other potential problems.

  • The contractor shall notify the purchaser in writing of all necessary repairs and services needed to bring the engine and related accessories within applicable manufacturers’ speci­fications.
  • All belts and filters shall be replaced.

6.6.2* If the existing engine or engine system is to be replaced, it shall be replaced with one that meets or exceeds the require­ments of the NFPA automotive fire apparatus standard that was in effect at the time the apparatus was manufactured.

6.6.2.1 The contractor shall furnish certification that the engine meets or exceeds the EPA standards that were in effect at the time of the original apparatus construction, as well as certification that the installation meets the engine manufactur­er’s requirements.

  • Cooling System.

6.7.1 If the cooling system or any related component(s) are to be upgraded, the contractor shall inspect all portions of the cooling system that are not scheduled to be replaced for leaks, blockages, wear, and other conditions that could affect the cooling of the vehicle’s engine.

  • The contractor shall notify the purchaser in writing of any problems or abnormal conditions discovered during the inspection.
  • The cooling system shall be flushed, and new coolant that meets the engine manufacturer’s requirements shall be added.
  • If the cooling system or cooling system components are upgraded, the contractor shall certify that the upgraded cool­ing system meets the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable, and the engine manufac­turer.
  • The upgraded engine cooling system shall maintain a temperature in the engine at or below the engine manufactur­er’s maximum temperature rating under all conditions of oper­ation for which the fire apparatus is designed.
  • Lubrication System.
  • If the lubrication system or any related component(s) is to be upgraded, the contractor shall inspect all portions of the lubrication system that are not scheduled to be replaced for leaks, wear, and other problems that could affect the perform­ance of the system.
  • The contractor shall notify the purchaser in writing of any problems or abnormal conditions discovered during the inspection.
  • The upgraded lubrication system shall meet the engine manufacturer’s requirements.
  • Fuel and Air Systems.
  • If the fuel system or air intake system is to be upgraded, the contractor shall inspect all portions of the system not scheduled to be replaced for leaks, wear, and other problems that could affect the performance of the system.
  • The contractor shall notify the purchaser in writing of any problems or abnormal conditions discovered during the inspection.
  • The contractor shall certify that the upgraded fuel system or air intake system meets the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable, and the engine manufacturer.
  • Exhaust System.
  • If the exhaust system components are to be upgraded, the contractor shall inspect all portions of the system that are not scheduled to be replaced for leaks, loose hangers, rusted tubing, wear, and other problems that could affect the performance of the exhaust system.
  • The contractor shall notify the purchaser in writing of any problems or abnormal conditions discovered during the inspection.
  • The contractor shall certify that the upgraded exhaust system meets the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable, and the engine manufac­turer.

6.11 Vehicle Components.

  • Braking System.

6.11.1.1* If the braking system is to be upgraded, the contrac­tor shall inspect all portions of the braking system and associ­ated accessories that are not scheduled to be replaced for wear, leakage, loss of performance, and other problems that could affect the performance of the braking system.

6.11.1.1.1 The contractor shall notify the purchaser in writing of any problems or abnormal conditions found during the inspection.

6.11.1.2* If a new braking system or new brake components are installed, the installation shall meet the manufacturers’ recommendations.

6.11.1.3 The contractor shall certify that the braking system meets or exceeds the performance requirements of the edition of the NFPA automotive fire apparatus standard in effect at the time of contract signing for the original manufacture of the apparatus.

  • Suspension, Wheels, and Tires.

6.11.2.1* If the suspension, wheels, or tires are to be upgra­ded, the contractor shall inspect the axles, wheels, tires, springs, hangers, mountings, and suspension system accessories that are not scheduled to be replaced for wear, stress cracks, sagging, improper bolt torque, and other problems.

  • The contractor shall notify the purchaser in writing of any damaged components or other problems that are discov­ered during the inspection.
  • The manufacturer shall certify that the upgraded suspension, wheels, and tires of the fire apparatus meet all applicable component manufacturers’ standards as well as all GVWR, GCWR, and GAWR ratings.
  • The refurbished apparatus shall meet all applicable federal and state weight ratings.

6.11.2.5* When the fire apparatus, as delivered, is loaded to its GVWR or GCWR, if applicable, the parking brake system shall hold the apparatus on at least a 20 percent grade.

  • If the steering system is to be upgraded, the contrac­tor shall inspect the entire system, including the steering box, steering gear, drag links, power steering pump, hose, and acces­sories that are not scheduled to be replaced for wear, leakage, loss of performance, and other problems.
  • The contractor shall notify the purchaser in writing of any damaged components or other problems that are discov­ered during the inspection.
  • The contractor shall certify that the upgraded steering system meets the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable, and the component manu­facturer.
  • The upgraded steering system shall be capable of turning the front wheels to an angle of at least 30 degrees to either the right or left for nondriving front axles, and at least 28 degrees for driving front axles.

6.11.3.5 Power steering or power-assisted steering shall be provided.

  • Transmission/Transfer Case.
  • If either the transmission or the transfer case is to be upgraded, the contractor shall inspect all components of the transmission or transfer case, their mountings, and the associ­ated accessories that are not scheduled to be replaced for wear, damage, and fluid leaks.
  • All fluid levels and filters shall be checked.
  • The contractor shall notify the purchaser in writing of any damaged components or other problems that are discov­ered during the inspection.
  • If an upgraded transmission is installed in the fire apparatus, the contractor shall certify that the installation meets the transmission manufacturer’s specifications for instal­lation in the specific type of apparatus, as well as the current requirements of NFPA 1901 or NFPA 1906, whichever is appli­cable.
  • Fuel Tank.
  • If the fuel tank is to be upgraded, the contractor shall inspect all components of the fuel tank, its mountings, and associated accessories that are not scheduled to be replaced for wear, damage, and fluid leaks.
  • The contractor shall notify the purchaser in writing of any damaged components or other problems that are discov­ered during the inspection.
  • Fuel tanks that are replaced shall be replaced with new tanks that meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.

6.11.6* Tow Hooks. If upgraded front or rear tow hooks or tow eyes are installed on the fire apparatus, they shall be attached to the frame structure to allow towing (not lifting) of the apparatus without damage.

6.12 Low-Voltage Electrical Systems and Warning Devices.

6.12.1* General. Any upgraded 12 V or 24 V electrical systems or warning devices installed on the fire apparatus shall be appropriate for the service intended and shall meet the specific requirements of Section 6.12.

6.12.2* If the low-voltage electrical system is upgraded, the contractor shall inspect the components of the electrical system not scheduled to be replaced for problems that could affect the vehicle’s electrical performance.

  • The inspection shall include the condition of wires, connectors, relays, fuses, and/or circuit breakers and related components.
  • The contractor shall notify the purchaser in writing of any damaged components or problems that are discovered during the inspection.

6.12.3 Power Supply.

  • If the alternator is to be upgraded, it shall be replaced by a 12V or 24 V alternator.
  • The alternator shall have a minimum output at idle to meet the minimum continuous electrical load of the fire appa­ratus as defined in 6.12.3.3 at 200°F (93°C) ambient tempera­ture within the engine compartment, and it shall be provided with full automatic regulation.
  • The minimum continuous electrical load shall consist of the total amperage required to simultaneously operate the following in a stationary mode during emergency operations:
    • The propulsion engine and transmission
    • All legally required clearance and marker lights, head­lights, and other electrical devices except windshield wipers and four-way hazard flashers
    • The radio(s) at a duty cycle of 10 percent transmit and 90 percent receive (for calculation and testing purposes, a default value of 5 A continuous)
    • If the fire apparatus is not a wildland fire apparatus, the lighting necessary to produce 1 fc (10 lx) of illumination on all walking surfaces on the apparatus and on the ground at all egress points off of the apparatus, 5 fc (50 lx) of illumination on all control and instrument panels, and 50 percent of the total compartment lighting loads.
    • The minimum optical warning system required where the apparatus is blocking right-of-way
    • The continuous electrical current required to simultane­ously operate any fire pumps, aerial devices, and hydraulic pumps
    • * Other warning devices and electrical loads defined by the purchaser as critical to the mission of the apparatus
  • Load Management.

6.12.3.4.1* If the total connected electrical load of the upgra­ded low-voltage electrical system exceeds the minimum contin­uous electrical output rating of the installed alternator(s) operating under the conditions specified in 6.12.3.2, an auto­matic electrical load management system shall be required.

6.12.3.4.2 The minimum continuous electrical load defined in 6.12.3.3 shall not be subject to automatic load management.

6.12.4* Optical Warning Devices. If the optical warning devi­ces are to be upgraded, the contractor shall inspect the compo­nents of the optical warning system that are not scheduled to be replaced for problems that could affect the vehicle’s warn­ing devices.

  • The inspection shall include the condition of wires, connectors, relays, fuses and/or circuit breakers, motors, lenses, and related components.
  • The contractor shall notify the purchaser in writing of any problems or discrepancies that are discovered during the inspection.

6.12.5 Audible W’arning Devices.

  • Audible warning equipment in the form of at least one automotive traffic horn and one electric or electronic siren shall be provided.
  • A means shall be provided to allow the activation of the siren within convenient reach of the driver.
  • If upgraded or additional air horns, electric siren(s), or electronic siren speaker(s) are installed, they shall be moun­ted as low and as far forward on the fire apparatus as practical.
  • Upgraded or additional audible warning equipment shall not be mounted on the roof of the apparatus.

6.13* Driving and Crew Compartments.

6.13.1 If the driving and/or crew compartment(s) is to be upgraded, the contractor shall inspect the driving and crew compartments, their mountings, and associated accessories for wear, damage, and corrosion.

6.13.1.1 The contractor shall notify the purchaser in writing of any damaged components that are discovered during the inspection.

6.13.2* If a new driving and/or crew compartment is installed, it shall be a fully enclosed design that meets the current requirements of NFPA 1901 or NFPA 1906, whichever is appli­cable.

  • The driving compartment shall have a seating capacity for a minimum of two fire fighters except at a tiller driving position, which shall have seating for at least one person.
  • The driving and crew compartments shall have a combined seating capacity at least equal to the maximum number of persons expected to ride within the fire apparatus (See Section 4.2.)
  • If the new driving and/or crew compartment is of a tilt- up design, it shall be arranged so that all the manufacturer’s recommended routine maintenance checks of lubricant and fluid levels can be performed easily by the operator without raising the driving and/or crew compartment and without the need for hand tools.
  • After installation of the new driving and/or crew compartment, airflow through the radiator shall be sufficient to comply with the cooling system requirements as defined in 6.7.3.
  • Fully Enclosed Crew Compartment Conversions. If an

existing two-door open canopy-style crew compartment is converted into a fully enclosed crew compartment, the added- on portion of the crew compartment shall comply with all applicable requirements of NFPA 1901.

6.14 Body, Compartmentation, and Hose Storage.

6.14.1 If the body, compartmentation, or hose storage areas are to be upgraded, the contractor shall inspect all portions of the body, compartmentation, or hose storage areas that are not scheduled to be replaced for wear, damage, and corrosion.

6.14.1.1 The contractor shall notify the purchaser in writing of any damaged components that are discovered during the inspection.

6.14.2* If a new body, compartmentation, or hose storage area is installed, it shall meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.

  • If additional compartments are added to an existing body, they shall meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.
  • Metal Finish.
  • The fire apparatus, when refinished, shall comply with the current requirements for metal finish in NFPA 1901 or NFPA 1906, including the application of reflective striping.
  • If the metal finish is to be upgraded, all exposed ferrous metal surfaces that are not plated or stainless steel shall be cleaned and prepared and shall be painted or coated.
  • The paint or coating, including any primer, shall be applied in accordance with the paint or coating manufacturer’s recommendations.
  • The purchaser shall specify whether nonferrous body components are to be painted and any lettering, number­ing, or decorative striping to be furnished.
  • Fire Pump and Associated Equipment. If the fire pump or associated equipment is to be upgraded, the contractor shall inspect all portions of the fire pump, its mountings, and any associated accessories that are not scheduled to be replaced for wear, damage, and leaks.
  • The contractor shall notify the purchaser in writing of any damaged components or other problems that are discov­ered during the inspection.
  • All upgraded parts or components shall be compatible with the original fire pump.
  • The fire pump packing shall be adjusted to the pump manufacturer’s recommended tolerances.
  • Water Tank.

6.16.1 If the existing water tank is to be reused, the contractor shall inspect the tank for serviceability and shall report any defects to the purchaser in writing.

6.16.2* If a new water tank is installed, it shall meet the current requirements of NFPA 1901 or NFPA 1906, whichever is applicable.

6.16.3 Installation of a new water tank shall not result in the refurbished apparatus exceeding the GAWR and GCWR or GVWR of the chassis under the conditions specified in Section 6.2.

  • Aerial Devices.
  • If the aerial device is to be upgraded, the contractor shall inspect all components of the aerial device, its mountings, controls, and associated accessories that are not scheduled to be replaced for wear, damage, corrosion, and other deficien­cies.
  • The contractor shall notify the purchaser in writing of any damaged components or other problems that are discov­ered during the inspection.
  • All new or replacement parts or components shall be compatible with the design of the original aerial device and shall meet the requirements of the NFPA automotive fire appa­ratus standard in effect at the time of the contract signing for the original manufacture of the apparatus.
  • If a replacement aerial device is installed, the new device shall meet the current requirements of NFPA 1901 and shall be so certified by the contractor.
  • After the aerial device upgrade work has been performed, a full inspection and test as defined in NFPA 1911 shall be performed.
  • Equipment Carried on the Fire Apparatus.

6.18.1 If new ground ladders are furnished, they shall meet the requirements of NFPA 1931.

6.18.1.1 Stepladders and other types of multipurpose ladders meeting ANSI A14.2, Ladders — Portable Metal — Safety Require­ments, or ANSI A14.5, Ladders — Portable Reinforced Plastic — Safety Requirements, with duty ratings of Type 1A or 1AA shall be permitted to be substituted for a folding ladder.

6.18.1.2 Stepladders and other types of multipurpose ladders shall be permitted to be carried in addition to the minimum fire department ground ladders specified in NFPA 1901 provi­ded they meet either ANSI A14.2 or ANSI A14.5 with duty ratings of Type 1A or 1AA.

  • If new hose is furnished, it shall meet the requirements of NFPA 1961.
  • If new nozzles are furnished, they shall meet the requirements of NFPA 1964.

6.19 Tests and Delivery Data Requirements.

  • Pump Certification Tests.
  • If the refurbished fire apparatus is equipped with a new or upgraded fire pump that has a rated capacity of 750 gpm (3000 L/ min) or greater, the pump system shall be tested after the pump and all its associated piping and equip­ment have been installed on the apparatus.
  • The tests shall be conducted at the contractor’s approved facility and certified by an independent testing organization that is approved by the purchaser.
  • The certification shall include at least the tests defined in 6.19.2 through 6.19.6.
  • If the apparatus is equipped with a water tank, the water tank-to-pump flow test as defined in 6.19.7 shall be inclu­ded in the certification.
  • If the refurbished fire apparatus is equipped with a new or upgraded fire pump that has a rated capacity of less than 750 gpm (3000 L/min), the pump system shall be tested after the pump and all its associated piping and equipment have been installed on the apparatus.
  • The tests shall be conducted at the manufacturer’s approved facility and certified by the contractor.
  • The certification shall include at least the tests defined in 6.19.2 and 6.19.4 through 6.19.6.
  • If the apparatus is equipped with a water tank, the water tank-to-pump flow test as defined in 6.19.7 shall be inclu­ded in the certification.
  • If the refurbished fire apparatus is equipped with an existing fire pump that is neither upgraded nor replaced, the pump shall be tested after the refurbishing is complete.
  • The tests shall be conducted at the manufacturer’s approved facility and certified by the contractor.
  • The certification shall include at least the tests defined in 6.19.2 and 6.19.4 through 6.19.6.
  • If the apparatus is equipped with a water tank, the water tank-to-pump flow test as defined in 6.19.7 shall be inclu­ded in the certification.
  • Pumping Tests.

6.19.2.1 If the refurbished fire apparatus is equipped with a new or upgraded fire pump, the pumping test shall be conduc­ted in accordance with the test requirements defined in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.

6.19.2.2 If the original fire pump is retained, the pumping test shall be conducted in accordance with the test requirements of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.

  • Pumping Engine Overload Test.
  • If the refurbished fire apparatus is equipped with a new or upgraded fire pump, a pumping engine overload test meeting the test requirements in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable, shall be conducted.
  • If the refurbished fire apparatus retains its original pump(s), a pumping engine overload test shall be conducted in accordance with the test requirements of the NFPA automo­tive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.
  • Pressure Control Device Test.
  • If the refurbished fire apparatus is equipped with a new or upgraded pressure control device on the fire pump, the pressure control device shall be tested in accordance with the test requirements defined in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the original pressure control device is retained, it shall be tested in accordance with the pressure control system test requirements of NFPA 1911 if it has not been tested within the previous 12 months, or if any work has been done to the pressure control device.
  • Priming System Test.
  • If the refurbished fire apparatus is equipped with a new or upgraded priming system on the fire pump, the priming system shall be tested in accordance with the test requirements defined in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the original priming system is retained, it shall be tested in accordance with the priming system test requirements of NFPA 1911, if the priming system has not been tested within the previous 12 months, or if any work has been done to the priming system.
  • Vacuum Test.
  • If the refurbished fire apparatus has a new or upgra­ded fire pump or pump piping, a vacuum test shall be conduc­ted in accordance with the test requirements in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the original fire pump and pump piping are retained, a vacuum test shall be conducted in accordance with the vacuum test requirements of NFPA 1911, if that test has not been conducted within the previous 12 months, or if any work has been done to the pump or piping.
  • Water Tank-to-Pump Flow Test.

6.19.7.1 If the refurbished apparatus has a new or upgraded water tank(s), pump(s), or pump piping, a water tank-to-pump flow test shall be conducted in accordance with the test requirements in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.

6.19.7.2 If the original water tank(s), pump(s), and pump piping are reused, a water tank-to-pump flow test shall be conducted in accordance with the water tank-to-pump flow test requirements of NFPA 1911, if that test has not been conduc­ted within the previous 12 months, or if any work has been done to the pump(s), water tank(s), and pump piping.

  • Engine Speed Advancement Interlock Test. An engine speed advancement interlock test meeting the test require­ments in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable, shall be conducted.
  • Aerial Device Certification Tests.
  • If a new or upgraded aerial device is installed on the refurbished fire apparatus, the completed apparatus shall be tested according to the test requirements of NFPA 1901 at the manufacturer’s approved facility and certified by an independ­ent testing organization approved by the purchaser.
  • If the original aerial device is reused, the completed apparatus shall be inspected and tested in accordance with the complete requirements of NFPA 1911, if the aerial device has not been tested to the complete requirements of NFPA 1911 within the previous 12 months, or if any work has been done to the aerial device or related systems.
  • Refurbisher’s Pre-Delivery Tests.
  • Water Tank Capacity Test.
  • A water tank capacity test meeting the current requirements of NFPA 1901 or NFPA 1906, whichever is appli­cable, shall be conducted on all refurbished fire apparatus having newly installed water tanks.
  • Fire apparatus retaining their original water tanks shall be tested to the requirements in the edition of the appli­cable standard in effect at the time of the original contract signing if any work has been done to the tank or its related systems.
  • Low-Voltage Electrical System Tests.

6.19.10.2.1* If any work is conducted that substantially changes the original low-voltage electrical system of the fire apparatus or adds new loads (such as adding a load manage­ment system, new lights, new relay boards, etc.), the apparatus shall be tested according to the requirements of the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.

6.19.10.2.2 If any work is conducted on the low-voltage electri­cal system that leaves the original electrical system configura­tion intact (such as tightening connections, replacing individual wires, etc.), the apparatus shall be tested according to the requirements of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.

  • Line-Voltage Electrical System Tests.

6.19.10.3.1* If a new line-voltage electrical system is added or any work is conducted that substantially changes the original line-voltage electrical system on the fire apparatus or adds new line-voltage electrical loads such as lights, permanently connec­ted equipment, receptacles, cord reels, and so forth, the appa­ratus shall be tested according to the applicable requirements of the current edition of NFPA 1901.

6.19.10.3.2 If any work is conducted on the line-voltage electri­cal system that leaves the original line-voltage electrical system configuration intact (such as tightening connections, replacing individual wires, etc.), the apparatus shall be tested according to the requirements of the edition of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus. If a new pump is installed and the generator shares the same power source as the pump, the line-voltage electrical system test shall be run concurrendy with the pump test.

6.19.10.4* Foam System Tests.

  • If the refurbished fire apparatus has a new foam system, the system shall be tested in accordance with the test requirements in the current edition of NFPA 1901 or NFPA 1906, whichever is applicable.
  • If the refurbished fire apparatus retains its original foam system and system components, and if any work has been done to the foam system or it has been upgraded, the system shall be tested to ensure it meets the requirements of the edition of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manu­facture of the apparatus.

6.19.11 Road Tests.

6.19.11.1* If the refurbished fire apparatus has upgraded powertrain components (engine, transmission, driveline, or axles), it shall be road tested in accordance with 6.19.11.2 through 6.19.11.6.

  • If the refurbished fire apparatus reuses the original powertrain (engine, transmission, driveline, and axles), the powertrain shall be tested to ensure it meets the requirements of the edition of the NFPA automotive fire apparatus standard in effect at the time of the contract signing for the original manufacture of the apparatus.
  • The tests shall be conducted at a location and in a manner that does not violate local, state, or federal traffic laws.
  • The fire apparatus shall be loaded to its estimated in- service weight.
  • The tests shall be conducted on dry, level, paved roads that are in good condition.
  • The engine shall not be operated in excess of the maximum governed speed.
  • Acceleration tests shall consist of two runs in oppo­site directions over the same route.
  • The vehicle shall attain a speed of 35 mph (55 km/hr) from a standing start within 25 seconds.
  • The vehicle shall attain a minimum top speed of not less than 50 mph (80 km/hr).
  • If the fire apparatus is equipped with an auxiliary braking system, the manufacturer shall road test the system to confirm that the system is functioning as intended by the auxili­ary braking system manufacturer.
  • If the apparatus is equipped with an air brake system, the service brakes shall bring the apparatus, when loaded to its GVWR, to a complete stop from an initial speed of 20 mph (32.2 km/hr), in a distance not exceeding 35 ft (10.7 m) by actual measurement on a paved, level, dry surface road that is free ofloose material, oil, or grease.

6.19.11.6 If the apparatus is equipped with a hydraulic brake system, the service brakes shall bring the apparatus, when loaded to its GVWR, to a complete stop from an initial speed of 30 mph (48.2 km/hr), in a distance not exceeding 88 ft (26.8 m) by actual measurement on a paved, level, dry surface road that is free ofloose material, oil, or grease.

6.19.12 Tests on Delivery.

  • If acceptance tests are required at the point of deliv­ery, the purchaser shall specify the details of the tests to be performed and they shall not be performed in a manner that requires the apparatus or a component to operate outside its designed operating range.
  • Aerial device stability tests shall not be run at other than the refurbisher’s or the aerial device manufacturer’s facility.
  • Data Required of the Contractor.
  • If applicable, the contractor shall supply, at the time of delivery, at least one copy of the following:
    • Engine manufacturer’s certified brake horsepower curve for a new engine installation showing the maximum governed speed
    • Contractor’s record of fire apparatus refurbishing includ­ing, if applicable, all technical information required for inspection to comply with NFPA 1911
    • Pump manufacturer’s certification of suction capabilities for new pump installations
    • Pump manufacturer’s certification of hydrostatic test for new pump installations
    • Certification of required inspections and tests
    • If equipped with a pump, a copy of the chassis manufac­turer’s approval for stationary pumping applications
    • Weight documents from a certified scale showing actual loading on the front axle, rear axle(s), and overall vehicle (with the water tank full but without personnel, equip­ment, and hose) supplied with the completed vehicle to determine compliance with Section 4.8
    • The latest edition of the FAMA Fire Apparatus Safety Guide
  • A label shall be affixed to the vehicle certifying that the vehicle is in compliance with all applicable Federal Motor Vehi­cle Safety Standards (FMVSS) in effect at the time of comple­tion.
  • If the original fire pump is replaced with a new fire pump, a new test plate shall be provided on the pump opera­tor’s panel that gives the rated discharges and pressures together with the speed of the engine, as determined by the certification tests required by19.1, the position of the parallel-series pump as used, and the governed speed of the engine as stated by the engine manufacturer on a certified brake horsepower curve.

6.20.3.1 The test plate shall be stamped with complete infor­mation at the contractor’s facility and attached to the vehicle prior to delivery.

  • Safety Signs. The contractor shall ensure that the follow­ing safety signs, as appropriate to the apparatus type and features and as described and located per FAMA TC010, Stand­ard Product Safety Sign Catalog for A utomotive Fire Apparatus, shall be on the apparatus prior to delivery:
    • FAMA01 — Battery Explosion
    • FAMA02 — Rotating Shafts
    • FAMA05 — Spinning Fan
    • FAMA06 — Seats Without Belts Not Occupied
    • FAMA07 — Seated and Belted
    • FAMA10 — Cab Equipment Mounting
    • FAMA12 — Fire Service Tire Rating
    • FAMA14 — Cab Seating
    • FAMA15 — Helmet Worn in Cab (1901 Municipal Appa­ratus)
    • FAMA17 — Vehicle Backing
    • FAMA18 — Intake and Discharge Cap Pressure
    • FAMA22 — Hose Restraint Required
    • FAMA23 — Access Step Method
    • FAMA24 — Riding on Exterior
    • FAMA25 — Trained Personnel Only — NFPA Required
    • FAMA26 — No-Step
    • FAMA28 — Rope Tie-Down 9000
    • FAMA30 — Stabilizer Crush
    • FAMA31 — Stabilizer Pins & Pads
    • FAMA32 — Stabilizer Pads
    • FAMA34 — Fall Restraint Required
    • FAMA35 — Aerial Electrocution
    • FAMA36 — Aerial Electrocution
    • FAMA37 — Aerial Device Load Capacity
    • FAMA38 — Aerial Ladder Rung Pinch ‘
    • FAMA39 — Aerial Inspection
    • FAMA41 — Cab Tilt
    • FAMA42 — Siren Noise
    • FAMA43 — Helmet Worn in Cab (1906 Wildlands Appa­ratus)
    • FAMA44 — Pump-and-Roll Firefighting Position Exte­rior
    • FAMA45 — Pump-and-Roll Firefighting Position Driver
    • FAMA46 — Aerial Device Pinch
    • FAMA47 — Aerial Device Operator Attention Required

Annex A Explanatory Material

Annex A is not a part of the requirements of this NFPA document but is included for informational purposes only. This annex contains explanatory material, numbered to correspond with the applicable text paragraphs.

A 1.1 This document is designed to be used to aid in develop­ing specifications for the refurbishing of fire apparatus. It is the intent of this standard to ensure that refurbished fire apparatus meet all applicable federal motor vehicle regulations as well as the applicable portions of NFPA 1901 or NFPA 1906, whichever is applicable.

This standard will do the following:

  • Identify minimum levels of refurbishing
  • Establish minimum requirements for inspection and/or replacement of all vehicle components
  • Create informational checklists that will identify areas on the vehicle that should be addressed when considering refurbishing
  • Create a guideline for any personnel engaged in prepar­ing specifications for fire department or municipal agency emergency vehicle refurbishing
  1. 1.5 Metric units of measurement in this standard are in accordance with the modernized metric system known as the International System of Units (SI). The liter, a unit that is outside of, but recognized by, SI is commonly used in interna­tional fire protection. Table A. 1.5(a) and Table A. 1.5(b) provide conversion factors as an aid to the user. Table A. 1.5(c) provides other conversion factors that could be useful to the reader. Table A. 1.5(d) provides a list of the abbreviations used in this standard and their meaning.

A3.2.1 Approved. The National Fire Protection Association does not approve, inspect, or certify any installations, proce­dures, equipment, or materials; nor does it approve or evaluate testing laboratories. In determining the acceptability of installa­tions, procedures, equipment, or materials, the authority having jurisdiction may base acceptance on compliance with NFPA or other appropriate standards. In the absence of such standards, said authority may require evidence of proper instal­lation, procedure, or use. The authority having jurisdiction may also refer to the listings or labeling practices of an organi­zation that is concerned with product evaluations and is thus in a position to determine compliance with appropriate standards for the current production of listed items.

Table A 1.5(a) Conversion Factors: U.S. Units to SI Units

U.S.

SI

1 gallon per minute (gpm)

3.785 liters per minute (L/

 

min)

1 imperial gallon per minute

4.546 liters per minute (L/

(igpm)

min)

1 pound per square inch (psi)

6.895 kilopascals (kPa)

1 inch of mercury (in. Hg) at

3.376 kilopascals (kPa)

60°F (15.6°C)

 

1 inch (in.)

25.40 millimeters (mm)

1 foot (ft)

0.3048 meter (m)

1 cubic foot (ft3)

0.02832 cubic meter (m3)

1 mile per hour (mph)

1.609 kilometer per hour

(km/hr)

1 pound (lb)

0.4536 kilogram (kg)

1 footcandle (fc)

10.76 lux (lx)

Table A 1.5(b) Conversion Factors: SI Units to U.S. Units

SI

U.S.

1 liter per minute (L/min)

0.2642 gallon per minute

 

(gpm)

1 liter per minute (L/min)

0.2200 imperial gallon per

 

minute (igpm)

1 kilopascal (kPa)

0.1450 pound per square inch

 

(psi)

1 kilopascal (kPa)

0.2962 inch of mercury (in.

 

Hg) at 60°F (15.6°C)

1 millimeter (mm)

0.03937 inch (in.)

1 meter (m)

3.281 feet (ft)

1 cubic meter (m3)

35.31 cubic feet (ft3)

1 kilometer per hour

0.6214 mile per hour (mph)

(km/hr)

 

1 kilogram (kg)

2.205 pounds (lb)

1 lux (lx)

0.09290 footcandle (fc)

Table A. 1.5(c) Useful Conversion Factors

1 gallon per minute

= 0.833 imperial gallon per minute

(gpm)

(igpm)

1 imperial gallon per

= 1.2 gallons per minute (gpm)

minute (igpm)

 

1 foot (ft) of water

= 0.433 pound per square inch

 

(psi)

1 pound per square

= 2.31 feet (ft) of water

inch (psi)

 

1 pound per square

= 2.036 inches of mercury (in. Hg)

inch (psi)

 

1 inch of mercury (in.

= 1.135 feet (ft) of water

Hg)

 

1 inch of mercury (in.

= 0.491 pound per square inch

Hg)

(psi)

1 gallon of water

= 8.34 pounds (lb)

1 gallon of water

= 231 cubic inches (in.3)

1 metric ton (mton)

= 1000 kilograms (kg)

1 kilopascal (kPa)

= 0.01 bar

1 bar

= 100 kilopascals (kPa)

Table A. 1.5(d) Abbreviations Used in Standard

Abbreviation

Term

Abbreviation

Term

A

ampere

km/hr

kilometers

   

per hour

ac

alternating

kPa

kilopascal

 

current

  

C

Centigrade

L

liter

dc

direct current

L/min

liters per

   

minute

F

Fahrenheit

lx

lux

fc

footcandle

in

meter

ft

feet

m m

millimeter

gpm

gallons per

mph

miles per hour

 

minute

  

in.

inch

psi

pounds per

   

square inch

in. Hg

inches of

V

volt

 

mercury

  

kg

kilograms

  

A.3.2.2 Authority Having Jurisdiction (AHJ). The phrase “authority having jurisdiction,” or its acronym AHJ, is used in NFPA documents in a broad manner, since jurisdictions and approval agencies vary, as do their responsibilities. Where public safety is primary, the authority having jurisdiction may be a federal, state, local, or other regional department or indi­vidual such as a fire chief; fire marshal; chief of a fire preven­tion bureau, labor department, or health department; building official; electrical inspector; or others having statutory author­ity. For insurance purposes, an insurance inspection depart­ment, rating bureau, or other insurance company representative may be the authority having jurisdiction. In many circumstances, the property owner or his or her designa­ted agent assumes the role of the authority having jurisdiction; at government installations, the commanding officer or depart­mental official may be the authority havingjurisdiction.

A.3.3.13 Contractor. The contractor might not necessarily refurbish the vehicle or any portion of the vehicle but is responsible for the completion, delivery, acceptance, and warranty of the entire unit. Since fire apparatus are frequendy refurbished in-house by the local fire department or city garage, the term contractor would include that department and its personnel if the project were to be done by the local fire department, fire brigade, or other municipal agency.

A.3.3.22 GAWR (Gross Axle Weight Rating). It is a require­ment of the National Highway Traffic Safety Administration that the GAWR be posted in the vehicle on a permanendy affixed label. The axle system includes, but is not limited to, the axle, tires, suspension, wheels, frame, brakes, and applied engine torque.

The final-stage manufacturer might have to de-rate the GAWR for the purpose of preventing vehicle instability as a result of changes made during the refurbishing. In addition, if an apparatus received a Level I refurbishing, it might have new axles, tires, suspension, and so forth, that allow a higher GAWR than the original rating. The final-stage manufacturer is the one who will know this.

A.3.3.23 GCWR (Gross Combination Weight Rating). A combi­nation vehicle is the combination of a towing vehicle and one or more towed units (trailers). When a trailer is detachable, the GCWR limits the maximum loaded weight for any replacement trailer. The in-service weight or gross combination weight, including any connected trailer, should always be equal to or less than the GCWR.

A.3.3.24 Grade. A 45-degree slope is equal to a 100 percent grade.

A.3.3.25 GVWR (Gross Vehicle Weight Rating). It is a require­ment of the National Highway Traffic Safety Administration that the GVWR of a vehicle be posted in the vehicle on a permanendy affixed label. The GVWR can be equal to or less than the sum of the front GAWR and the rear GAWR. The in- service weight or gross vehicle weight should always be equal to or less than the GVWR.

A.3.3.32 Net Pump Pressure. When operating from a hydrant, the net pump pressure is typically less than the discharge pres­sure. For example, if the discharge pressure gauge reads 150 psi (1034 kPa) and the intake (suction) gauge reads 20 psi (138 kPa), the net pump pressure equals 130 psi (896 kPa). When operating from draft, the net pump pressure will be above the discharge pressure. For example, if the discharge pressure gauge reads 145 psi (1000 kPa) and the intake (suction) gauge reads 10 in. Hg (34 kPa) vacuum, the net pump pressure will be 150 psi (1034 kPa) (1 in. Hg = 0.5 psi = 3.4 kPa).

A.3.3.37 Purchaser. In the case of refurbished apparatus, the purchaser can be the original owner of the vehicle scheduled for refurbishing, or it may be a person, organization, or juris­diction considering the purchase of a refurbished fire appara­tus.

A.3.3.39 Quint. The primary purpose of this type of fire appa­ratus is to combat structural and associated fires and to support fire-fighting and rescue operations by positioning personnel- handling materials, providing continuous egress, or discharg­ing water at positions elevated from the ground.

A.3.3.42.1 Level I Refurbishing. A vehicle that has undergone Level I refurbishing receives a new make and model designa­tion and a new Certificate of Origin for the current calendar year.

A.3.3.42.2 Level II Refurbishing. A vehicle that has under­gone Level II refurbishing retains its original make and model identification as well as its original title and year of manufac­ture designation.

A.3.3.45 Special Services Fire Apparatus. These services could be rescue, command, hazardous material containment, air supply, electrical generation and floodlighting, or transporta­tion of support equipment and personnel.

A.3.3.51 Upgrade. It is recommended that consideration be given to using upgraded components or systems that meet current standards to the maximum extent possible, to ensure that the refurbished apparatus will approach the performance and safety requirements of newly manufactured apparatus.

A.4.1 It is recommended that upgraded components or systems meeting current NFPA standards be installed whenever possible for enhanced safety and serviceability. Replacement parts, components, or systems should meet the current require­ments of NFPA 1901 or NFPA 1906, whichever is applicable. Meeting the requirements will help to make the fire apparatus as safe as possible, in addition to making for easier availability of parts for maintenance and repair.

Where local operating conditions necessitate apparatus of unusual design, the purchaser should carefully define the special requirements in the specifications. Height, width, under-vehicle clearance, wheelbase, turning radius, length, and so forth, can occasionally need special attention. For example, a community having low overpasses needs to have a refurbished apparatus capable of traveling underneath these overpasses. The specifications for the refurbished apparatus should state the maximum travel height that is allowable.

A.4.2 The refurbishing of a fire apparatus generally involves a major investment and should be treated as such. Fire apparatus are complex mechanical equipment that should not be refur­bished in a haphazard manner. A decision to refurbish should be made only after a detailed study of the fire department’s apparatus needs, taking into consideration other equipment the department owns or plans to buy.

A.4.3.1 Depending on the scope of the refurbishing, the detailed description could include estimated in-service weight, wheelbase, principal dimensions, angle of approach, angle of departure, ramp breakover angle, transmission ratios, axle ratios, and, if applicable, the rated capacity of the aerial device. The purpose of these contractor specifications is to define what the contractor intends to furnish and deliver to the purchaser.

A.4.3.2 Depending on the scope of the refurbishing, a quali­fied and responsible representative of the contractor should instruct personnel, specified by the purchaser, in the opera­tion, care, and maintenance of the refurbished fire apparatus and equipment delivered. If the refurbishing does not change any of the operating procedures of the apparatus, instruction on the operation, care, and maintenance of the refurbished fire apparatus and equipment might not be required.

A.4.7.1 The engine compartment and the underside of the vehicle are not considered areas of normal nonmaintenance operation.

A.4.7.4 Uniformity of safety signage is a desirable objective. Examples of common safety sign solutions are depicted in FAMA TC010, Standard Product Safety Sign Catalog for Automotive Fire Apparatus, and should be considered where deemed appli­cable by the manufacturer. [1901:A.4.9.41

A.4.8 The carrying capacity of a fire apparatus is one of the least understood features of design, and one of the most impor­tant. All apparatus have a GVWR or maximum total weight, which should not be exceeded by the apparatus refurbisher or by the user after the vehicle has been placed in service. For tractor-drawn vehicles, the GCWR weight should not be excee­ded. There are many factors that make up the GVWR, includ­ing the design of the springs and suspension system, the rated axle capacity, the rated tire loading, and the distribution of the weight between the front and rear wheels.

One of the most critical factors is the size of the water tank. Water weighs approximately 8lA lb/gal (1 kg/L). A value of 10 lb/gal (1.2 kg/L) can be used when estimating the weight of the tank and its water, making a 500 gal (2000 L) tank and its water about 2.5 tons (2400 kg).

If the completed apparatus is not to be overloaded, the purchaser should provide the contractor with the weight of equipment to be carried.

Overloading the apparatus by the refurbisher through design, or by the user through specifying a larger water tank on a small chassis, or by the user adding a great deal of equipment after the apparatus has been returned to service will materially reduce the life of the vehicle and will undoubtedly result in increased maintenance costs, particularly with respect to trans­missions, clutches, and brakes. Overloading can also seriously affect handling characteristics, making steering and braking p art icul arly diffi cult.

The distribution of the weight between the front and rear wheels is also a factor for major consideration, as improper design will seriously affect the handling characteristics. Too little weight on the front wheels can cause a front-end skid and, over bumpy roads, can cause the front of the vehicle to veer from side to side; at the very least it will be difficult to keep the vehicle under control. Too much weight on the front wheels will reduce the traction of the rear wheels and can result in a rear-end skid or difficulty in traveling over unpaved roads or in mud and snow. Further, overloading of either the front or rear wheels might require that the tires be of different sizes.

Fire apparatus should be able to perform their intended service under adverse conditions that could require operation off paved streets or roads. Chassis components should be selec­ted with the rigors of service in mind.

A.4.8.2(4) A weight of 250 lb (114 kg) for a fully equipped fire fighter is used in other NFPA standards. The 200 lb (90 kg) pet- person weight used in 4.8.2(4) does not include the weight of SCBA and tools carried by a fire fighter, as the weight of this equipment is accounted for in 4.8.2(8).

A.5.1 The National Highway Traffic Safety Administration (NHTSA) in the United States has a regulation, 49 CFR 571.7e, for determining when the modifications to a used vehicle are so extensive that the resulting vehicle will be considered new for the purposes of the Federal Motor Vehicle Safety Standards (FMVSS). Section 571.7(e) states: “Combining new and used components. When a new cab is used in the assembly of a truck, the truck will be considered newly manufactured …

unless the engine, transmission, and drive axle(s) (as a mini­mum) of the assembled vehicle are not new, and at least two of these components were taken from the same vehicle.”

A.5.2 Vehicles are designed with a specific GAWR and GCWR, or GVWR, based on the safe carrying capacity of components and/or the entire vehicle. Increasing the weight over these limits can result in loss of stability, lack of adequate braking, or other handling problems, all of which have the potential for injury or death to fire fighters and civilians. Requesting a contractor to exceed these limits or to compound an over­weight problem creates a potential liability issue for both the purchaser and the contractor. Vehicles at or above their GAWR and GCWR or GVWR should not be considered for refurbish­ing unless upgraded components are installed to increase the weight ratings, or the refurbishing will result in a net decrease in vehicle weight.

A.5.3.4 The projections of total equipment payload and mounting locations are essential for proper engineering of a refurbished fire apparatus. The purchaser of the fire apparatus should maintain the side-to-side loading requirement in 5.3.4 as equipment is loaded or installed on the apparatus.

x 100 = percent difference

The percentage difference in tire load should be calculated as shown in the following formula:

[A.5.3.4]

I heavier \ _ / lighter \ weight/ \ weight

total weight

A.5.3.5 NFPA 1901 requires electronic stability control for those apparatus that fail to pass the established roll stability criteria. The following items impact the roll stability safety of the apparatus and should be considered when making deci­sions on how to refurbish the apparatus.

Custom fire apparatus cab. The nature of the custom fire appa­ratus cab makes it much stronger in rollovers than typical conventional commercial chassis cabs. There is much anecdo­tal evidence to indicate that the crashworthiness of a typical custom fire apparatus cab is significandy greater than a typical commercial cab, and most custom chassis manufacturers can provide test data on cab integrity.

Lateral acceleration alert device. There are both mechanical and electronic devices available that will measure the lateral acceler­ation of a vehicle. Although these devices will not prevent roll­over, they can be used effectively as a driver training tool to indicate when the vehicle is approaching the roll threshold and as a reminder to the driver that excessive lateral acceleration can lead to a rollover event.

Side roll protection. Many custom fire apparatus manufacturers offer side air bags or curtains that inflate during a roll event and that are usually combined with seat belt pretensioning devices and suspension seat pull-down devices. This option can reduce injury during a rollover as long as the occupants are seated and belted.

Roll stability control. This technology electronically senses the lateral acceleration of the vehicle and takes action by depower- ing the engine and applying the brakes if the vehicle approaches a roll threshold. The effectiveness of this product is limited to events on relatively flat pavement, since it cannot do much to help the situation once a vehicle is off the road and leaning into a ditch.

Electronic stalnlity control (ESC). ESC uses a steering wheel posi­tion sensor, a vehicle yaw sensor, a lateral accelerometer, and individual wheel brake controls in conjunction with the anti- lock brake system (ABS). The system tracks the direction that the driver intends to steer and uses brake application at indi­vidual wheels to help straighten out the vehicle.

Driver skill and experience. While the design and features of the vehicle are important to safe driving, the most important aspect of crash prevention is the skill and experience of the operator. The operator’s attitude, training, experience, and qualifica­tions, and the application of those qualities, are the most important elements in crash prevention. The operator must ensure that the physical limits of the vehicle are not exceeded. Driver skill is developed only through training and practice.

A.5.6.2 It should be noted that older engines might not meet current EPA standards and might not be able to be economi­cally upgraded to current standards.

A.5.11.1.3.1 A purchaser might elect to configure the fire apparatus to tow a trailer. However, even if the combination vehicle is within the GCWR, it might be impossible for the combination vehicle to be operated safely or to hold on a grade when parked, if the trailer is not equipped with its own braking system. The purchaser should ensure that any added trailers have sufficient braking capacity for safe operation.

A.5.11.2.2 Due to the hazards associated with split rims and the injuries resulting from them, they should be considered for replacement with solid rims whenever possible.

Consideration should be given to replacement of tires per the tire manufacturer’s recommendations. Tires are subject to other factors besides wear, including, but not limited to, dry rot, sidewall damage, and cuts. Tires with any of these condi­tions should be replaced.

A.5.13 A driving/crew compartment replacement with increased seating capacity can have an impact on the vehicle weight, which should be taken into consideration. A fully enclosed driving/crew compartment to seat more than the original number of personnel can require upgrades to suspen­sion, axles, tires, and other components. Driving/crew compartment extensions with full enclosures are also accepta­ble means to accomplish this safety design feature. The use of three-point seat belts is encouraged. All forward-facing seats adjacent to a side wall should be provided with a Type 2 pelvic and upper torso restraint-style seat belt assembly conforming to the Federal Motor Vehicle Safety Standard (FMVSS) No. 209, “Seat belt assemblies.”

The purchaser should consider specifying remote controls on the mirrors to facilitate correct mirror adjustment. When necessary, heated mirrors should also be considered.

A.5.14.4 All exposed ferrous metal surfaces that are not chrome-plated or stainless steel should be cleaned and prepared and should be painted to the color(s) specified by the purchaser. If nonferrous body components are furnished, the purchaser should specify which surfaces are to be painted. The paint, including the primer, should be applied in accord­ance with the paint manufacturer’s recommendations.

A.5.16.2 When dealing with a new water tank installation, the specified changes must take into consideration the overall weight of the tank cradle, additional plumbing required, and water or agent weight, as well as the tank itself. Apparatus stability and braking ability can be adversely affected by exceed­ing the maximum allowable configurations. Contractors as well as purchasers can be held accountable and liable if maximum limits are exceeded. Therefore, exceeding the maximum should not be considered and if additional tank size is still preferred or required, weight reductions in other areas such as hose load, miscellaneous equipment, or newer lightweight components should be utilized to maintain, yet not exceed, the maximum allowable limits.

A5.19.10.4 NFPA 1901 did not have any requirements for foam prior to the 1991 edition. It is recommended that the foam system manufacturer’s test requirements be utilized for apparatus that were purchased prior to the effective date of NFPA 1901, 1991 edition, and retain their original foam systems.

A5.19.ll Any time the engine or drivetrain is altered or replaced with different components, the purchaser should require road testing to ensure the refurbished apparatus meets minimum acceptable standards.

A6.1 The National Highway Traffic Safety Administration (NHTSA) in the United States has a regulation, 49 CFR 571.7e, for determining when the modifications to a used vehicle are so extensive that the resulting vehicle will be considered new for the purposes of the Federal Motor Vehicle Safety Standards (FMVSS). Section 571.7(e)7 states: “Combining new and used components. When a new cab is used in the assembly of a truck, the truck will be considered newly manufactured … unless the engine, transmission, and drive axle(s) (as a mini­mum) of the assembled vehicle are not new, and at least two of these components were taken from the same vehicle.”

A6.2 Vehicles are designed with specific GAWR and GCWR, or GVWR ratings based on the safe carrying capacity of compo­nents and/or the entire vehicle. Increasing the weight over these limits can result in loss of stability, lack of adequate brak­ing, or other handling problems, all of which have the poten­tial for injury or death to fire fighters and civilians. Requesting a contractor to exceed these limits or to compound an over­weight problem creates a potential liability issue for both the purchaser and the contractor. Vehicles at or above their GAWR and GCWR, or GVWR ratings should not be considered for refurbishing unless upgraded components are installed to increase the weight ratings, or the refurbishing will result in a net decrease in vehicle weight.

A6.3 Vehicle stability is one of the most critical factors in appa­ratus safety. When a chassis manufacturer’s requirement on center of gravity and weight distribution are known, they should be complied with to ensure a stable apparatus.

A6.3.1 All other factors being equal, an apparatus with a lower height will be more stable and less prone to overturning.

A6.3.2 Front axle loads should not be less than the minimum axle loads specified by the chassis manufacturer, under full load and all other loading conditions. Apparatus with extreme weight bias at front or rear can be difficult to control on curves or on road surfaces with poor adhesion.

A6.3.4 The projections of total equipment payload and mounting locations are essential for proper engineering of a refurbished fire apparatus. The purchaser of the fire apparatus should maintain the side-to-side loading requirement in 6.3.4 as equipment is loaded or installed on the apparatus.

x 100 = percent difference

The percentage difference in tire load should be calculated as shown in the following formula:

[A 6.3.4]

I heavier\ _ / lighter^ \ weight/ \ weight/

total weight

A6.6.1 The purchaser should consider the following tests when the engine or engine system is to be refurbished:

  • Compression test
  • Blowby test
  • Fuel pressure test
  • Oil analysis

A.6.6.2 It should be noted that older engines might not meet current EPA standards and may not be able to be economically upgraded to current standards.

A6.11.1.1 Problems with the vehicle braking system have the potential for causing serious accidents, resulting in injury or death to both fire fighters and civilians. In addition, there is a corresponding liability issue in the operation of a vehicle with an inadequate braking system. It is recommended that all required braking system repairs be made before the apparatus is returned to service.

A6.11.1.2 Consideration should be given to installing an anti- lock braking system (ABS) when the braking system is to be upgraded.

A6.11.2.1 Due to the hazards associated with split rims and the injuries resulting from them, they should be considered for replacement with solid rims whenever possible.

A6.11.2.5 See A.5.11.1.3.1.

A6.11.6 If the purchaser wants the tow hooks or tow eyes to be accessible without having to open compartment doors, the specifications should state that fact.

A6.12.1 This section defines the requirements for upgraded alternators, batteries, load management, and instrumentation to detect incipient electrical system failure. The intent is to require that an upgraded electrical system will operate the apparatus using power supplied by the alternator, shed non­essential electrical loads where necessary, and provide early warning of electrical failure in time to permit corrective action.

A6.12.2 All components that are upgraded should be replaced with components meeting the current edition of NFPA 1901 or NFPA 1906, as appropriate. The current standard provides additional lighting for safety and makes provision for two modes of operation: responding and blocking the right-of-way. Consideration should also be given to having the contractor furnish a wiring schematic of the rewired areas of the apparatus to enable vehicle repair technicians to more easily troubleshoot the electrical system or make additions to the system.

A6.12.3.3(7) The purchaser needs to analyze the electrical loads that have to be maintained to fulfill the mission of the refurbished apparatus and to define those loads for the refur- bisher of the apparatus. The purchaser needs to understand, however, that there is a limit to the output capacity of an alter­nator system on the apparatus’ engine, and that this standard requires that the apparatus be capable of maintaining the mini­mum continuous electrical load under the conditions defined in 6.12.3.2. When that load is exceeded and larger alternators are not available, the purchaser and the refurbisher need to work together to determine how to reduce the minimum continuous electrical load so that it can be sustained under the conditions defined in 6.12.3.2.

A.6.12.3.4.1 Reduced crew sizes have forced the apparatus operator to assume many new fireground tasks besides that of operating the apparatus. Even if the operator is at the appara­tus, he is too busy with higher priority tasks to pay much atten­tion to monitoring the condition of the electrical system.

Electrical loads on modern fire apparatus frequently exceed the alternator capacity and can be supplied only by the deep discharge of the apparatus batteries. The high-cycle batteries that are designed to provide the large amount of amperage to crank modern diesel engines are severely damaged when deeply discharged. The automatic load management is inten­ded to protect the electrical system from needless damage while maintaining the operation of essential devices.

It is important that the priority of all managed loads be specified by the purchaser so that, as electrical loads are discon­nected from the apparatus’ electrical system, they are shed in an order least likely to affect emergency operations. Optical warning devices in excess of the minimum required in NFPA 1901 or NFPA 1906, whichever is applicable, can and should be load managed.

A.6.12.4 Consideration should be given to upgrading the opti­cal warning devices to the current edition of NFPA 1901 or NFPA 1906, whichever is applicable, both for improved safety during emergency responses, as well as to minimize current draw when operating at the scene. The upgraded lighting should provide an increased measure of safety, as well as mini­mize loads to the low-voltage electrical system.

A.6.13 The purchaser should consider specifying remote controls on the mirrors to facilitate correct mirror adjustment. When necessary, heated mirrors should also be considered.

A.6.13.2 Cab replacements with increased seating capacity can have an impact on the vehicle weight, and this should be taken into consideration. A fully enclosed cab for more than the orig­inal number of personnel can require upgrades to suspension, axles, tires, and other components. Canopy cab extensions with patio door-type closures or separate telephone booth-type personnel enclosures are also acceptable means to accomplish this safety design feature. The use of three-point seat belts, where available, is encouraged.

A.6.14.2 It is recommended that any upgrades to the existing body, compartmentation, or hose storage area be made accord­ing to current NFPA standards.

A.6.16.2 When dealing with a new tank installation, the speci­fied changes must take into consideration the overall weight of the tank cradle, additional plumbing required, and water or agent weight, as well as the tank itself. Apparatus stability and braking ability can be adversely affected by tank modifications. Contractors as well as purchasers can be held accountable and liable if maximum limits are exceeded. Therefore, exceeding the maximum should not be considered, and if additional tank size is still preferred or required, weight reductions in other areas such as hose load, miscellaneous equipment, or newer lightweight components should be utilized to maintain, yet not exceed, the maximum allowable limits. (See Sections 6.2 and 6.3.)

A.6.19.10.2.1 A substantial change would include replacing the alternator, adding or replacing the load management system, upgrading the electrical control systems, or increasing the total connected load by 20 percent or more over the original as- delivered load.

A.6.19.10.3.1 A substantial change would include replacing the power source, replacing the line-voltage control system, or increasing total line-voltage load by 20 percent or more over the original as-delivered load.

A.6.19.10.4 There were no foam system requirements for appa­ratus built prior to the adoption of the 1991 edition of NFPA 1901.

  1. 19.11.1 Any time the engine or drivetrain is altered or replaced with different components, the purchaser should require road testing to ensure the refurbished apparatus meets minimum acceptable standards.

Annex B Fire Apparatus Refurbishing Specifications

This annex is not a part of the requirements of this NFPA document but is included for informational purposes only.

  1. l Fire apparatus refurbishing can range from simple cosmetic-type restorations to complete Level I refur­bishing. Therefore, the amount of information that the contractor and purchaser require can vary greatly. Depending on the scope of the proposed work, consideration should be given to the details discussed in some or all of the following paragraphs. It is recommended that the form in Figure B.l be used to identify the information needed to properly develop specifications for those portions of the fire apparatus that are to be modified or upgraded during the refurbishing.

The local fire chief and fire department staff know the conditions under which the apparatus will be used. However, competent advice should also be obtained from knowledgeable and informed sources such as other experienced fire service personnel, trade journals, training instructors, maintenance personnel, and fire equipment and component manufacturers. The fire insurance rating authority should also be consulted.

The study should look not only at current operations and risks protected but also at how these might change over the life of the fire apparatus.

B.l.l Writing the Specifications.

B.l. 1.1 This standard provides the minimum technical requirements that refurbished fire apparatus are expected to meet. It is recognized that many purchasers will desire addi­tional features beyond these minimum requirements. The requirements in this standard, together with the annex mate­rial, should be carefully studied. Details of where the apparatus has to exceed the minimum requirements or where a specific arrangement is required should be carefully defined in the specifications for the refurbished apparatus. These details might include special performance requirements, the number of seats and seating arrangement for fire fighters riding on the apparatus, or the provision of space for extra hose or equip­ment the apparatus will be required to carry.

NFPA 1912 Fire Apparatus Refurbishing